Auto-verify your Cause & Effect (C&E) matrix against the current P&ID. Every trip function, every Safety Instrumented Function (SIF), every SIL-rated function cross-checked. Deleted or renamed instrument tags flagged before SIS audit, before HAZOP review, before SIS Functional Safety Assessment. Zero-competition AI capability per Excel S6 #6: no other vendor globally productises C&E vs P&ID consistency check at scale. Built for SIS engineers, Functional Safety Engineers, and HAZOP facilitators on safety-critical process projects (LNG, hydrogen, ammonia, sour service, pressurised gas storage). IEC 61511 + IEC 61508 aligned. SIL-impact severity scoring per discrepancy.
Each row of the C&E matrix maps trigger conditions (causes) to safety actions (effects). Pathnovo extracts every C&E row, parses the trigger / action logic, and cross-references against the current P&ID for instrument loop tagging, signal direction, and control system assignment. Every trip function validated end-to-end before SIS Functional Safety Assessment.
Discrepancies classified by SIL impact: SIL-CRITICAL (discrepancy affects a SIL-3 or SIL-2 rated SIF; safety case integrity at risk), SIL-MAJOR (discrepancy affects SIL-1 SIF), SIL-MINOR (discrepancy in non-SIL-rated trip function), CLARIFICATION (ambiguous; needs Functional Safety Engineer judgment). Severity matrix configurable per project's safety case methodology.
C&E matrices typically built early in design (FEED phase or early detailed engineering); P&IDs continue evolving through revisions. By construction phase, C&E matrices reference instrument tags that have been renamed, replaced, or deleted in current P&ID revisions. Pathnovo automatically flags every C&E row referencing a tag not present in the current P&ID, with the SIL-impact severity. The single most common cause of SIS Functional Safety Assessment failure.
C&E matrix verification aligned to IEC 61511 (Functional Safety - Safety Instrumented Systems for the Process Industry) and IEC 61508 (Functional Safety of Electrical / Electronic / Programmable Electronic Safety-related Systems). Verification output formatted for SIS Functional Safety Assessment (FSA) deliverable; ready for SIS owner / Functional Safety Manager review.
Per Excel S6 ranking, C&E vs P&ID verification is a zero-competition workflow: no other vendor globally has productised this specific SIS-safety-critical layer. Alomana handles broader cross-document review without SIS-specific scoring. IPS / Acuvate / NovekAI / IntuigenceAI / Scry AI / Quantiphi do not address C&E matrix verification. Pathnovo's C&E vs P&ID verification is the deepest SIS safety document AI in production globally.
Cross-document verification report ready before SIS Functional Safety Assessment workshop and before HAZOP review. SIS engineers + Functional Safety Engineers + HAZOP facilitators arrive at workshops with verified-consistent input documents; workshop time focuses on safety analysis (the actual purpose) instead of reconciling C&E vs P&ID inconsistencies.
Pre-SIS Functional Safety Assessment gate: C&E matrix verified against current P&ID before FSA workshop begins
Pre-HAZOP review gate: C&E + P&ID consistency confirmed before HAZOP facilitator runs the safety study
LNG / hydrogen / ammonia / sour-service projects: SIL-3 / SIL-2 SIF integrity verified across multi-revision P&ID set
Brownfield revamp: existing-plant C&E matrices cross-checked against revamp-modified P&IDs to surface SIS impact
Owner-operator handover gate: C&E + P&ID consistency confirmed as part of formal acceptance
Multi-EPC consolidation: cross-EPC C&E matrices reconciled against unified P&ID set for owner-operator master safety case
Insurance / risk audit: C&E vs P&ID consistency confirmed as part of process safety insurance renewal
Post-incident audit: C&E + P&ID consistency reviewed retrospectively to identify root-cause of SIS bypass / failure
A C&E matrix is the formal SIS design document that maps trigger conditions (causes: e.g. 'PT-101 high pressure', 'LT-202 low level', 'TT-303 high temperature') to safety actions (effects: e.g. 'close XV-401 isolation valve', 'trip P-502 pump', 'open PV-601 relief valve'). Each row defines a Safety Instrumented Function (SIF). The C&E matrix is typically built during FEED phase, refined during detailed engineering, and finalised before SIS Functional Safety Assessment. It encodes the entire SIS safety case in one tabular document. Maintained by SIS Engineers / Functional Safety Engineers; reviewed during HAZOP and SIS FSA.
Three reasons. (1) Safety integrity: C&E rows that reference deleted or renamed instrument tags become broken SIFs at construction or commissioning; SIL-rated safety functions silently fail. (2) FSA gate: SIS Functional Safety Assessment is contractual on tier-1 owner-operator projects; FSA gate failure delays commissioning weeks-to-months. (3) Liability: in-service SIS failure traceable to undetected C&E vs P&ID inconsistency creates substantial process safety liability for the SIS owner + Functional Safety Manager. Manual cross-checking is the current state-of-art; routinely catches 60-80% of inconsistencies on $50M-capex unit (where 5-15% C&E rows reference tags that diverged in P&ID revisions). Pathnovo's automated verification at 99% discrepancy detection compresses 4-8 weeks of manual SIS Engineer time into 48 hours of structured deliverable.
A SIF is a single safety-related action implemented through a Safety Instrumented System: one row of the C&E matrix. Example: 'IF PT-101 reads above 50 bar THEN close XV-401' is one SIF. Each SIF carries a SIL (Safety Integrity Level) rating from SIL-1 (lowest) to SIL-4 (highest, typically reserved for nuclear). Most process plant SIFs are SIL-1 or SIL-2; safety-critical SIFs (LNG hot spots, sour service H2S protection, hydrogen leak detection) often SIL-3. Every SIF must be verifiable: the trigger sensor must exist and report correctly, the logic solver must be reachable, the final element (valve, pump, motor) must operate reliably. C&E vs P&ID verification confirms the trigger + final element exist on the current P&ID with correct loop tagging.
IEC 61511 is the international standard for Functional Safety of Safety Instrumented Systems (SIS) in the process industry. Defines lifecycle phases (FEED → SIS design → SIS Functional Safety Assessment → operations → modification → decommissioning) and conformance requirements at each phase. C&E matrix is the central design artifact; SIS FSA is the gate review. Pathnovo's C&E vs P&ID verification operates at the FSA gate review phase: produces the structured discrepancy report that the FSA team uses as input to assess whether the SIS design conforms to the safety case requirements. IEC 61508 is the broader functional safety umbrella (covers electrical / electronic / programmable electronic safety-related systems generally); IEC 61511 is the process-industry-specific application.
Cross-document verification (parent pillar) covers 5+ document layers: P&ID vs datasheet, line list, equipment list, instrument index, plus the C&E layer covered specifically here. C&E vs P&ID verification is the SIS-safety-specific layer with: (1) SIL-impact severity scoring (instead of generic CRITICAL / MAJOR / MINOR), (2) IEC 61511 + IEC 61508 alignment (instead of generic engineering review), (3) Functional Safety Assessment-shaped output (instead of generic discrepancy report), (4) SIF-by-SIF analysis (instead of tag-by-tag reconciliation). For SIS engineers + Functional Safety Engineers, this is the deeper layer they need; for general engineering review teams, the parent pillar covers the broader scope. Most projects use both: parent pillar for HAZOP-prep gate; this cluster for FSA gate.
SIS C&E matrix verification is included on every paid tier of the credit-based pricing model. A typical $50M-capex unit with 50-200 SIFs fits comfortably inside Starter (1,000 credits/month) or Professional (5,000 credits/month). Larger projects with 500+ SIFs (LNG complexes, large refinery revamps) sit on Scale (25,000+ credits). Multi-project SIS portfolios move to Enterprise. Free 14-day trial with 100 credits to validate on a C&E matrix + P&ID pair (typically 10-30 SIFs). Indian PSU rate-card compatibility available. SIS owner / Functional Safety Manager budgets the tier subscription as part of FSA-gate preparation cost. See our pricing page for full plan details.
Three buyer archetypes. (1) SIS Engineer / Functional Safety Engineer at EPC contractor: needs verified-consistent C&E + P&ID input before SIS FSA workshop runs; cross-document verification is the gate-prep deliverable. (2) Functional Safety Manager at owner-operator: requires C&E matrix + P&ID consistency as part of formal acceptance gate at handover from EPC. (3) Process Safety / Risk Engineer at process safety insurer or risk audit firm: uses C&E vs P&ID consistency as audit input for renewal / risk assessment. All three buyers are SIS-safety-specialist + budget-aware; they recognise the manual review burden + the in-service liability risk that this workflow eliminates.
Yes, this is the highest-value scope. SIL-3 SIFs (typical for LNG hot spots, sour-service H2S protection, hydrogen leak detection, ammonia release detection) carry the strictest functional safety requirements per IEC 61511. Pathnovo's automated verification of SIL-3 C&E rows against current P&ID is the deepest safety integrity check available without manual SIS Engineer review of every row across multiple P&ID revisions. The SIL-impact severity scoring ensures that any SIL-3 or SIL-2 discrepancy is the first item the FSA team sees in the report. For LNG / hydrogen / ammonia safety-critical projects, this is contractually de-risking on what is otherwise a multi-week manual SIS Engineer review with imperfect coverage.
Send us 10 documents from your current project. We extract, reconcile, and show you exactly what we find in 48 hours, before any contract.
If the accuracy isn't what we promised, you owe us nothing.
Connect with Pathnovo to discuss your engineering document intelligence needs.
Email: hello@pathnovo.com
Send us a message, and we'll get back to you shortly.
You can also stay connected through our official social media channels.
Our Offices
Bangalore Office
Unit 101, OXFORD TOWERS 139, Old HAL Airport Rd, Kodihalli, Bengaluru, Karnataka 560008